Operation Manual
81
71.06953.01 - EN
INSTALLATION INSTRUCTIONS
The DHW and CH lters are housed in special extractable cartridges. The CH cartridge is located on the CH return line
(gure 15F). To clean the lters, proceed as described below:
• switch off the boiler;
• shut the DHW inlet tap
• drain the water in the CH circuit by opening tap A in gure 15.
• remove the clip (1-F) from the lter as illustrated in the gure and take out the cartridge (2-F) containing the lter, taking
care not to apply excessive force;
• to extract the heating lter cartridge, rst remove the 3-way valve motor (1-2G - gure 15);
• eliminate any impurities and deposits from the lter;
• reposition the lter in the cartridge and put it back into its housing, securing it with the clip.
WARNING
when replacing and/or cleaning the O-rings on the hydraulic assembly, only use Molykote 111 as a lubricant, not oil or grease.
30. CLEANING THE FILTERS
To clean, proceed as follows:
• Turn off the DHW inlet tap
• Drain the DHW system by opening a hot water tap
• Turn off the DHW outlet tap
• Remove the clip 1E in gure 15.
• Remove the lter (2E gure 15).
Dismount the water-water heat exchanger, as described in the next section, and clean it separately.
To clean the exchanger and/or DHW circuit, use Cillit FFW-AL or Benckiser HF-AL.
31. REMOVING SCALE FROM THE DHW CIRCUIT
The stainless steel plate-type water-water heat exchanger can be easily disassembled with an M4 spanner by operating
as described below:
• drain the system, just the boiler if possible, through the drain tap;
• drain the DHW system;
• remove the two screws at the front securing the water-water heat exchanger and pull it out (gure 15B).
32. DISMOUNTING THE WATER-WATER HEAT EXCHANGER
DRAINING THE STORAGE BOILER
Drain the water in the storage boiler as follows:
- close the water inlet tap;
- open a user tap;
- open the relative drain tap (Fig. 2-B);
- loosen the nut on the DHW outlet pipe at the bottom of the storage boiler.