Operation Manual

1 Specific information
1.1 Recommendations
Note
Only qualified persons are authorised to assemble, install and
maintain the installation.
1.2
Ecodesign Directive
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
1.3
Technical data - Medium-temperature heat pump space heaters
Tab.1 Technical parameters for heat pump space heaters (parameters declared for medium-temperature application)
AWHP 4 MR AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
Air-to-water heat pump Yes Yes Yes Yes
Water-to-water heat pump No No No No
Brine-to-water heat pump No No No No
Low-temperature heat pump No No No No
Equipped with a supplementary heater Yes Yes Yes Yes
Heat pump combination heater No No No No
Rated heat output under average condi
tions
(1)
Prated
kW 3 4 6 6
Rated heat output under colder conditions
(1)
Prated
kW 3 4 6 4
Rated heat output under warmer conditions
(1)
Prated
kW 3 5 6 8
Declared capacity for heating for part load
at indoor temperature 20 °C and outdoor
temperature
T
j
T
j
= -7 °C
Pdh
kW 2.9 3.5 5.6 6.8
T
j
= +2 °C
Pdh
kW 3.5 4.5 6.1 8.2
T
j
= +7 °C
Pdh
kW 3.9 4.8 6.4 9.0
T
j
= +12 °C
Pdh
kW 4.8 5.2 6.7 10.1
T
j
= bivalent temperature
Pdh
kW 2.8 3.6 5.6 6.2
T
j
= operation limit temperature
Pdh
kW 2.8 3.6 5.6 6.2
Bivalent temperature
T
biv
°C -10 -10 -10 -10
Degradation coefficient
(2)
Cdh
1.0 1.0 1.0 1.0
Seasonal space heating energy efficiency
under average conditions
ƞ
s
% 150 137 136 132
Seasonal space heating energy efficiency
under colder conditions
ƞ
s
% 120 116 119 113
Seasonal space heating energy efficiency
under warmer conditions
ƞ
s
% 195 172 169 167
Declared coefficient of performance or pri
mary energy ratio for part load at indoor
temperature 20 °C and outdoor tempera
ture
T
j
1 Specific information
7616372 - ErP01 - 01072015 3