Operation Manual
AWHP 16
MR-2
AWHP 16
TR-2
AWHP 22 TR AWHP 27 TR
Annual energy consumption under warmer
conditions
Q
HE
kWh
GJ
4120 3837 6952
(1) The rated heat output
Prated
is equal to the design load for heating
Pdesignh
, and the rated heat output of a supplementary heater
Psup
is equal to the supplementary capacity for heating
sup(Tj).
(2) If
Cdh
is not determined by measurement, the default degradation coefficient is
Cdh
= 0.9.
1.4
Circulation pump
Note
The benchmark for the most efficient circulators is EEI ≤ 0.20.
1.5
Disposal and Recycling
Warning
Removal and disposal of the heat pump must be carried out by a
qualified professional in accordance with prevailing local and na
tional regulations.
1. Switch off the heat pump.
2. Cut the mains supply to the heat pump.
3. Disconnect the refrigeration connections.
4. Close the water mains.
5. Drain the installation.
6. Dismantle the heat pump.
1.6 Product fiche - Heat pump space heaters
Tab.3 Product fiche for heat pump space heaters
AWHP 4 MR AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
Space heating energy efficiency class under average cli
mate conditions
A
++
A
++
A
++
A
++
Rated heat output under average climate conditions
(Prated or Psup)
kW 3 4 6 6
Seasonal space heating energy efficiency under aver
age climate conditions
% 150 137 136 132
Annual energy consumption kWh 1489 2124 3316 3783
Sound power level L
WA
indoors
(1)
dB (A) 53 53 53 53
Rated heat output, under colder - warmer climate condi
tions
kW 3 - 3 4 - 5 6 - 6 4 - 8
Seasonal space heating energy efficiency, under colder
- warmer climate conditions
% 120 - 195 116 - 172 119 - 169 113 - 167
Annual energy consumption colder - warmer kWh 2757 - 887 3721 - 1492 4621 - 1904 3804 - 2580
Sound power level L
WA
outdoors dB (A) 64 65 65 69
(1) If applicable
Fig.1 Recycling
MW-3000179-03
1 Specific information
6 7629848 - ErP01 - 01072015