Operation Manual
AWHP 16
MR-2
AWHP 16
TR-2
AWHP 22 TR AWHP 27 TR
Declared capacity for heating for part load at in
door temperature 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW 9.0 8.7 13.6
T
j
= +2 °C
Pdh
kW 11.9 13.6 20.2
T
j
= +7 °C
Pdh
kW 12.9 16.3 24.4
T
j
= +12 °C
Pdh
kW 15.4 18.6 32.3
T
j
= bivalent temperature
Pdh
kW 8.3 7.4 14.1
T
j
= operation limit temperature
Pdh
kW 8.3 7.4 14.1
Bivalent temperature
T
biv
°C -10 -10 -10
Degradation coefficient
(2)
Cdh
— 1.0 1.0 1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
% 130 125 125
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
% 113 103 110
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
% 161 164 156
Declared coefficient of performance or primary
energy ratio for part load at indoor temperature
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
- 1.88 1.85 1.92
T
j
= +2 °C
COPd
- 3.33 3.12 3.05
T
j
= +7 °C
COPd
- 4.34 4.12 4.15
T
j
= +12 °C
COPd
- 5.82 5.64 5.99
T
j
= bivalent temperature
COPd
- 1.54 1.68 1.92
T
j
= operation limit temperature
COPd
- 1.54 1.68 1.92
Operation limit temperature for air-to-water
heat pumps
TOL
°C -10 -10 -10
Heating water operating limit temperature
WTOL
°C 55 55 55
Electrical power consumption
Off mode
P
OFF
kW 0.009 0.009 0.009
Thermostat-off mode
P
TO
kW 0.049 0.049 0.049
Stand-by
P
SB
kW 0.013 0.013 0.013
Crankcase heater mode
P
CK
kW 0.055 0.055 0.055
Supplementary heater
Rated heat output
(2)
Psup
kW 0.0 0.0 0.0
Type of energy input Electricity Electricity Electricity
Other characteristics
Capacity control Variable Variable Variable
Sound power level, indoors - outdoors
L
WA
dB (A) 53 - 69 43 - 74 43 - 75
Annual energy consumption under average
conditions
Q
HE
kWh
GJ
5184 4808 9156
Annual energy consumption under colder con
ditions
Q
HE
kWh
GJ
5684 4702 13152
1 Specific information
7629848 - ErP01 - 01072015 5