Operation Manual

5
31/08/05 - 300005627-001-A CITY
Operating instructions
N : Temperature display
The display shows the temperature of the water in the domestic hot
water heating outlet when there is a request for domestic hot water.
O : 6-position switch
-
.
Stop/Anti-freeze/Bleed
-
Domestic hot water (Summer)
-
"
Heating and domestic hot water (Winter)
T : Domestic hot water temperature maintenance override
button (City Condens 1.24, 3.24) or
Maintenance override button for the primary storage tank
(City Condens 2.24)
For City Condens with Easymatic or Easyradio remote control
Pressing for 1 second in summer or summer/winter mode overrides
loading of the domestic hot water tank or of the primary storage tank
outside the time slot programmed on the control unit up to midnight
(indicator light T2 flash)
Light T1 lit : The burner is ignited to reheat the domestic hot
water tank (or primary storage tank)
Light T2 off : No override or programme running
Light T2 lit : Comfort programme activated
For City Condens without remote control
Light T1 lit : The burner is ignited to reheat the domestic hot water
tank (or primary storage tank)
A power cut does not modify the selected operating mode.
Q : Unlock button
To restart the boiler after safety shutdown.
V : Heating temperature setting
Setting range : 30 °C to 90 °C (Hard spot at 68°C)
X : Setting the domestic water temperature
Setting range : 40 °C to 60 °C
(Hard spot at 55°C) : 1.24, 3.24
Setting range : 40 °C to 58 °C
(Hard spot at 53°C) : 2.24
Z : Pressure indicator
Displays the pressure in the heating circuit from 0.5 to 2.5 bar. If the
red warming light (0.5 bar) is lit, top up with water using the filling
system (disconnector, consult your fitter (See next page).