Instruction Manual
6 Technical specifications
6.1 Technical specifications
6.1.1. Electricity supply
230 V AC (+/- 10%) - 50 Hz
400 V AC (+ 6%, - 10%) - 50 Hz (depending on the model)
6.1.2. Heat pump
Conditions of use:
4 Limit operating temperatures in Hot mode:
- Water: +18 °C / +55 °C
- Outside air:
-15 °C / +35 °C (4, 6 kW)
-20 °C / +35 °C (8, 11, 22, 27 kW)
4 Limit operating temperatures in Cooling mode:
- Water: +7 °C / +25 °C
- Outside air: +15 °C / +40 °C (At less than 18°C, it is necessary
to use the HK24 insulation kit option)
4 Maximum operating pressure: 3 bar
n
Performances in hot mode with outside air temperature
at +7°C and outlet water temperature at +35°C (in
accordance with EN 14511–2)
AWHP
4 MR 6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR 27 TR
Calorific output - A7/W35 kW 3.72 5.87 8.26 10.56 10.56 14.19 14.19 19.4 24.4
COP hot - A7/W35
4.30 4.18 4.27 4.30 4.30 4.22 4.22 3.94 3.90
Absorbed electrical power - A7/W35 kWe 0.87 1.41 1.93 2.46 2.46 3.36 3.36 4.92 6.26
Nominal amperage - A7/W35 A 4.11 6.57 8.99 11.81 11.81 16.17 16.17 7.75 9.86
6. Technical specifications AWHP-2 MIT-IN-2 iSystem
29
31/03/2014 - 7616372-001-02