Instruction Manual

4.2 Reading out measured values
The various values measured by the appliance are displayed in the
#MEASURES menu.
1. To access user level: Press the
>
key.
2. Select the menu #MEASURES.
4 Turn the rotary button to scroll through the menus or
modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer to
the chapter: "Browsing in the menus", page 13.
User level - Menu #MEASURES
Parameter Description Unit
OUTSIDE TEMP.
Outside temperature °C
ROOMTEMP.A
(1)
Room temperature of circuit A °C
ROOMTEMP.B
(1)
Room temperature of circuit B °C
ROOMTEMP.C
(1)
Room temperature of circuit C °C
MIT TEMP.
Inside module flow sensor measurement °C
PRESSURE
Water pressure in the installation bar (MPa)
WATER TEMP.
(1)
Water temperature in the DHW tank °C
STOR.TANK.TEMP
(1)
Water temperature in the storage tank °C
SWIMMING P.T.B
(1)
Water temperature of the swimming pool on circuit B °C
SWIMMING P.T.C
(1)
Water temperature of the swimming pool on circuit C °C
OUTLET TEMP.B
(1)
Temperature of the flow water in circuit B °C
OUTLET TEMP.C
(1)
Temperature of the flow water in circuit C °C
TEMP.SYSTEM
(1)
Temperature of the system flow water if multi-generator °C
T.DHW BOTTOM
(1)
Water temperature in the bottom of the DHW tank °C
TEMP.TANK AUX
(1)
Water temperature in the second DHW tank connected to the AUX circuit °C
DHW A TEMP.
(1)
Water temperature in the second DHW tank connected to circuit A °C
TEMP.SOL.TANK
(1)
Temperature of the hot water produced by solar power (TS) °C
SOLAR.COLL.T.
(1)
Solar panel temperature (TC) °C
SOLA.ENERGY
(1)
Solar energy accumulated in the tank kWh
FLOWMETER
Plate exchanger flow rate l/min
NB IMPULS.COMP
Number of heat pump start-ups
RUNTIME HP
Number of hours’ operation of the heat pump compressor h
IN 0-10V
(1)
Voltage at input 0-10 V V
SEQUENCE
Control system sequence
CTRL Software control number (SCU)
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
AWHP-2 MIT-IN-2 iSystem 4. Operating the appliance
31/03/2014 - 7616372-001-02
16