Specifications
UC864-E/G/WD/WDU AT Commands Reference Guide
80304ST10041a Rev. 7 - 2010-10-14
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 58 of 318
3.5.3.7. S Parameters
Basic commands that begin with the letter “S” are known as “S-Parameters”. The number
following the “S” indicates the “parameter number” being referenced. If the number is not
recognized as a valid parameter number, an ERROR result code is issued.
If no value is given for the subparameter of an S-Parameter, an ERROR result code will be issued
and the stored value left unchanged.
Note: what follows is a special way to select and set an S-parameter:
1. ATS
n
<CR> selects
n
as current parameter number. If the value of
n
is in the range (0,
2, 3, 4, 5, 7, 10, 12, 25, 30, 38), this command establishes S
n
as last selected
parameter. Every value out of this range and less than 256 can be used but has no
meaning and is maintained only for backward compatibility with landline modems.
2. AT=<value><CR> or ATS=<value><CR> set the contents of the selected S-parameter
Example:
ATS7<CR> establishes S7 as last selected parameter.
AT=40<CR> sets the contents of S7 to 40
ATS=15<CR> sets the contents of S7 to 15
3. AT? Returns the current value of the last S-parameter accessed.
Reference V25ter and RC56D/RC336D
3.5.3.7.1. Number Of Rings To Auto Answer - S0
S0 - Number Of Rings To Auto Answer
ATS0=[<n>] Set command sets the number of rings required before device automatically
answers an incoming call.
Parameter:
<n> - number of rings
0 - auto answer disabled (factory default)
1..255 - number of rings required before automatic answer.
ATS0? Read command returns the current value of S0 parameter.
Reference V25ter