Specifications

UC864-E/G/WD/WDU AT Commands Reference Guide
80304ST10041a Rev. 7 - 2010-10-14
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 108 of 318
+CALA - Alarm Management
“0” - it sets a recurrent alarm for all days in the week.
<silent> - integer type indicating if the alarm is silent or not.
0 - the alarm will not be silent;
1 - the alarm will be silent.
Note: a special form of the Set command, +CALA=””, deletes an alarm in the
ME
Note: The "alarm mode" is indicated by hardware pin CTS to the ON status
and DSR to the OFF status, while the "power saving" status is indicated by a
CTS - OFF ,DSR - OFF and USB_VBUSOFF status. The normal operating
status is indicated by DSRON or USB_VBUS – ON status.
During the "alarm mode" the device will not make any network scan and
will not register to any network and therefore is not able to dial or receive
any call or SMS, the only commands that can be issued to the MODULE in
this state are the #WAKE and #SHDN, every other command must not be
issued during this state.
AT+CALA? Read command returns the list of current active alarm settings in the ME, in
the format:
[+CALA: <time>,<n>,<type>,[<text>],<recurr>,<silent>]
AT+CALA=? Test command returns the list of supported index values (currently just 0),
alarm types, maximum length of the text to be displayed, maximum length
of <recurr> and supported <silent>s, in the format:
+CALA: (list of supported <n>s),(list of supported <type>s),<tlength>,
<rlength>,(list of supported <silent>s)
Example AT+CALA="02/09/07,23:30:00+00"
OK
Reference 3gpp TS 27.007
3.5.4.4.13. Restricted SIM Access - +CRSM
+CRSM - Restricted SIM Access
AT+CRSM=
<command>
[,<fileid>
[,<P1>,<P2>,<P3>
[,<data>]]]
Execution command transmits to the ME the SIM <command> and its
required parameters. ME handles internally all SIM-ME interface locking
and file selection routines. As response to the command, ME sends the
actual SIM information parameters and response data.
Parameters:
<command> - command passed on by the ME to the SIM
176 - READ BINARY
178 - READ RECORD
192 - GET RESPONSE