Specifications

BRAKE 40W
Single Phase
Switch
Note
Speciflcations
SW1
SW2 -
Single phase 110VAC,
Single phase 115VAC Input
Single phase 220VAC,
Single phase 230VAC Input
125 VAC 3A minimum
(inductive Load)
250 VAC 1.5A minimum
(inductive Load)
Switched
simultaneously
Three Phase
SW1 operates both motor and electromagnetic brake action. The motor will rotate when SW1 is
switched simultaneously to ON (short circuit). When SW1 is switched simultaneously with the
electromagnetic brake and holds the load.
(To release the brake while the motor is stopped, apply voltage between the two brake lead
wires (yellow). )
Direction of Rotation
To rotate the motor in a CCW direction, change any two connections between U, V and W.
Switch
Note
Speciflcations
SW1
250 VAC 1.5A minimum (inductive Load)
Switched
simultaneously
SW1 operates both motor and electromagnetic brake action. The motor will rotate when SW1 is
switched simultaneously to ON (short circuit). When SW1 is switched simultaneously with the
electromagnetic brake and holds the load.
(To release the brake while the motor is stopped, apply voltage between the two brake lead
wires (yellow). )
Direction of Rotation
For CW direction, flip SW2 to CW.
For CCW direction, flip SW2 to CCW.
ū Connection Dia
grams
Ŧ
The direction of motor rotation is as viewed from the shaft end of the motor.
Ŧ
CW represents the clockwise direction, while CCW represents the counterclockwise direction.
Ŧ
Connection diagrams are also valid for the equivalent round shaft motors.
Ŧ
Ro and Co indicates surge absorber circuit. [Ro=5~200ח, Co=0.1~0.2ל, 200WV (400WV)]