Installation guide

PowerSeries - PC1616/PC1832/PC1864
48
[501]- [514]Programmable Output Attributes
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009], [010] &
[011].PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF; Blank = Attribute not available):
Attribute: 12 3 4 5 678
ON
Not used Not used True Output Follows Timer Code Req. Not used Not used Not used
OFF
Inverted On / Off No Code Req.
PGM Option
[01] Residential Burglary / Fire Bell Output
Y
[02] For Future Use
[03] Sensor Reset [,][7][2]
Y
Y
N
[04] 2-Wire Smoke Support (PGM2 only)
Y
[05] System Armed Status
Y
[06] Ready To Arm
Y
[07] Kypad Buzzer Follower Mode
Y
[08] Courtesy Pulse
Y
[11] System Tamper (all sources, zones, keypad, modules)
Y
[12] TLM and Alarm
Y
[13] Kiss-off Output
YY
[14] Ground Start Pulse
YY
[15] Remote Operation (DLS Support)
Y
[16] For Future Use
Y
[17] Away Armed Status
Y
[18] Stay Armed Status
Y
[19] Command Output #1, [,][7][1]
YY Y
[20] Command Output #2, [,][7][2]
YY N
[21] Command Output #3, [,][7][3]
YY N
[22] Command Output #4, [,][7][4]
YY N
[23] 24 Hr Silent Input (PGM2 only)
Y
[24] 24 Hr Audible Input (PGM2 only)
Y
[25] Delayed Burglary & Fire Output
Y
[26] Battery Test Output
Y
[28] Holdup Output
Y
[30] Partition Status Alarm Memory Output
Y
[33] Bell Status and Programming Access Output
Y
[34] Away Armed With No Zone Bypassed Status
Y
Attribute:
PGM Option
123456 7 8
ON Serv. req. AC Fail TLM Fault FTC Zone Fault Zone Tmp. Zn. Low Bat. Loss of Clock
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
[09] System Trouble
YYYYYY Y Y
ON Burg. Evnt. Fire
Evnt.
Panic Evnt. Med. Evnt. Supv. Evnt. Priority Evnt. Holdup Evnt. Follows Timer*
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[10] System Event
YYYYYYY N
ON Fire Alarm Panic
Alarm
Burglary
Alarm
Open/Close Zone Aut.o
Bypass
Medical
Alarm
Police Code Active When
true
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[31] Alternate Communicator
NNNNNNN N
*If attribute [8] is turned ON, attributes [1-7] must also be turned ON.