Installation guide
PowerSeries - PC1616/PC1832/PC1864
46
[377] Communication Variables
Default
003 I_______I______I_______I Swinger Shutdown (Alarms and Rest) 001-014 Transmissions, 000=disabled
003
I_______I______I_______I Swinger Shutdown (Tampers and Rest) 001-014 Transmissions, 000=disabled
003
I_______I______I_______I Swinger Shutdown (Maint and Rest) 001-014 Transmissions, 000=disabled
000
I___0__I__6__I___0__I Communication Delay 001-255 seconds, 000=disabled
030
I_______I______I_______I AC Failure Communication Delay 001-255 minutes, 000=disabled
002
I_______I______I_______I TLM Trouble Delay No. of checks required - valid entries 003 - 255)
030
I_______I______I_______I Test Transmission Cycle (land line) 001-255 days/minutesâ€
030
I_______I______I_______I For Future Use
007
I_______I______I_______I Zone Low Battery Transmission Delay 000-255 days
030
I_______I______I_______I Delinquency Transmission Cycle 000-255 days/hours
000
I_______I______I_______I Communications Cancelled Window 000-255 minutes
†Dependent on programming in section [702], option [3].
Programming options indicated in GRAY are required for systems compliant with EN50131-1 and TS50131-3 standards.
[378] Test Transmission Time of Day
Default
Section [379] Periodic DLS Time of Day
Default
[380] First Communicator Options
[381] Second Communicator Options
9999 I_______I_______I_______I_______I Valid entries are 0000-2359 (9999 to disable)
9999 I_______I_______I_______I_______I Valid entries are 0000-2359 (9999 to disable)
Opt Def ON OFF
1
9 J
Communications Enabled
J
Communications Disabled
2
J
Restorals on Bell Time-out
9 J
Restorals Follow Zones
3
J
Pulse Dialing
9 J
DTMF Dialing
4
J
Switch to Pulse Dialing on 5th Attempt
9 J
DTMF Dial For All Attempts
5
J
3rd Telephone Number Enabled
9 J
3rd Telephone Number Disabled
6
J
Alternate Dial (1st & 3rd)
9 J
Call 1st Number, Back up to 3rd
7
J
For Future Use
9 J
8
J
Delinquency Follows Zone Activity (Hours)
9 J
Delinquency Follows Arming (Days)
Opt Def ON OFF
1
J
Open After Alarm Keypad Ringback Enabled
9 J
Open After Alarm Keypad Ringback Disabled
2
J
Open After Alarm Bell Ringback Enabled
9 J
Open After Alarm Bell Ringback Disabled
3
J
SIA Sends Programmed Reporting Codes
9 J
SIA Sends Automatic Reporting Codes
4
J
Closing Confirmation Enabled
9 J
Closing Confirmation Disabled
5
9 J
Talk/Listen on Phone Lines 1/3
J
No Talk/Listen on Phone Lines 1/3
6
9 J
Talk/Listen on Phone Line 2
J
No Talk/Listen on Phone Line 2
7
J
Contact ID Uses Programmed Reporting Codes
9 J
Contact ID Uses Automatic Reporting Codes
8
J
For Future Use
9
J