Installation guide

5.2 Programming Worksheets
35
[021] Eighth System Options
Programming option indicated in GRAY are required for systems compliant with EN50131-1 and TS50131-3 standards
[022] Ninth System Options
[023] Tenth System Options
[030] Zone Loop Response (Zones 1-8)
Opt Def ON OFF
1
J
Access Code Entry Blocked During Entry Delay
9
J
Access Code Entry Not Blocked During Entry Delay
2
J
EN Entry Procedure
9
J
Standard Entry Procedure
3
J
For Future Use
9
J
4
J
For Future Use
9
J
5
J
For Future Use
9
J
6
J
Keyswitch Disarming During Entry Delay Only
9
J
Keyswitch Disarming at Any Time
7
9
J
Installers Access Follows DLS Window
9
J
Installers can be Accessed Anytime
8
J
Arming Inhibit for All Troubles
9
J
Troubles Do Not Inhibit Arming
Opt Def ON OFF
1
9
J
Access Code Req’d for [,][1], [,][2], [,][3]
9
J
No Access Code Req’d for [,][1], [,][2], [,][3]
2
J
Keypad Blanking While Armed
9
J
No Keypad Blanking While Armed
3
J
For Future Use
9
J
4
J
Master Code Bypasses Holdup Zones Only
9
J
Any Code Bypasses Holdup Zones
5
J
Time Limit Enabled for PGM 05, 06, 17, 18
9
J
No Time Limit Enabled for PGM 05, 06, 17, 18
6
J
RF Delinquency enabled
9
J
RF Delinquency disabled
7
9
J
Open Zones Cancel Arming
9
J
Open Zones Cancel Arming Disabled
8
J
Audible Exit Delay for Stay Arming
9
J
Stay Arming Silent
Opt Def ON OFF
1
J
Fire Key Beeps Only
9
J
Fire Key Beeps and Sounds Bell
2
J
200 Baud Open/Close Identifier Toggle ON
9
J
200 Baud Open/Close Identifier Toggle OFF
3
J
Test Transmission While Armed Only
9
J
Test Transmission While Armed/Disarmed
4
J
Test Transmission in Hours
9
J
Test Transmission in Days
5
J
Switching from AWAY to STAY disabled
9
J
AWAY to STAY toggle Option Permitted
6
J
2-way Audio will NOT Disconnect for a New Event
9
J
2-way Audio Will Disconnect for a New Event
7
J
Trouble Beeps are Silent*
9
J
Trouble Beeps Sound Every 10 Seconds
8
J
For Future Use
9
J
Opt Def ON OFF
1
J
Zone 1 is Fast Loop Response
9
J
Zone 1 is Normal Loop Response
2
J
Zone 2 is Fast Loop Response
9
J
Zone 2 is Normal Loop Response
3
J
Zone 3 is Fast Loop Response
9
J
Zone 3 is Normal Loop Response
4
J
Zone 4 is Fast Loop Response
9
J
Zone 4 is Normal Loop Response
5
J
Zone 5 is Fast Loop Response
9
J
Zone 5 is Normal Loop Response
6
J
Zone 6 is Fast Loop Response
9
J
Zone 6 is Normal Loop Response
7
J
Zone 7 is Fast Loop Response
9
J
Zone 7 is Normal Loop Response
8
J
Zone 8 is Fast Loop Response
9
J
Zone 8 is Normal Loop Response