Installation guide
PowerSeries - PC1616/PC1832/PC1864
22
Section [382] Third Communicator Option Code
Section [383] Fourth Communicator Option Code
Section [389] T-Link Fault Check Timer
Programs the delay in seconds between T-Link module verification checks. Valid entries are [001]-[255].
Section [401] First Downloading Option Code
[5] ON: the system requests a Listen in/Two-way session the next time it calls the 1st/3rd Phone Number when the PC59xx transmits a
request. OFF: the system ignores the request from the PC59xx.
This Option is used with PC59xx series modules.
[6] ON: the system requests a Listen in/Two-way session the next time it calls the 2nd Phone Number when the PC59xx transmits a request.
OFF: the system will ignore the request from the PC59xx.
This Option is used with PC59xx series modules.
[7] ON: the system uses Contact ID format programmed reporting codes when transmitting reporting codes.
OFF: the system automatically generates all reporting codes transmitted.
[8] For Future Use
Option Description
[1] ON: the system will use the digit [5] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
OFF: the system will use the digit [4] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
[2] ON: the system will transmit all alarms during Walk Test. OFF: the system will not report alarm events during Walk Test.
[3] ON: the keypad will display the message ‘Communications Cancelled’ (programmable LCD) or ‘CC’ (fixed-message LCD) upon
successful transmission of the Communication Cancelled reporting event. OFF: the keypad will not display these messages.
[4] ON: the system dials the Call Waiting Cancel String on the first attempt to dial the central station. OFF: the system does not dial the Call
Waiting Cancel String.
[5] ON: enables support for the T-Link module. OFF: disables T-Link.
[6] ON: the AC Failure Transmission Delay Timer will use hours. OFF: the delay will be in minutes.
[7] ON: Sets the number of Dialing attempts to 1 when using Residential Dial Format. OFF: Residential Dial follows Dialing Attempt
Counter.
[8] For Future Use
Option Description
[1] ON: Events programmed to communicate to phone #1 will use the Partition Account Number programmed in section [311]. Events
Programmed to communicate to phone #2 will use the Partition Account Number in section [312]. OFF: Each events will use its respective
partition account code.
[2-8] For Future Use
Option Description
[1] ON: the system answers incoming calls for downloading (either Programmed Number of Rings or Double Call). OFF: the system does not
answer incoming calls for downloading.
These settings do not affect the 6 hour DLS downloading window on power up.
[2] ON: the user can enable downloading for the DLS Window using the [][6] command. OFF: the user cannot enable downloading.
[3] ON: the system will hang up after a successful DLS connection and call the computer back using the DLS Phone Number ( Section [402]).
OFF: the system stays connected to the computer.
[4] ON: the user can initiate a downloading session using the [][6] command. OFF: the user cannot initiate a downloading session.