Installation guide
Section 5 – Programming Descriptions
21
Section [378] Test Transmission Time
Program the time the system will report a Test Transmission reporting event. Program 4 digits – [HH][MM] using military standard.
For a test transmission at 11:00 pm, program data [23][00]). Valid entries are [00][00] to [23][59].
Section [379] Periodic DLS Time of Day
Programs the time the system will auto-call DLS. Program 4 digits – [HH][MM] using military standard. For a DLS auto-call at 11:00 pm,
program data [23][00]). Valid entries are [00][00] to [23][59]. Programming [99][99] will select a random time, [FF][FF] will disable it.
Please refer to the PC 1616/1832/1864 Reference Manual for a complete description of Periodic DLS.
Section [380] First Communicator Option Code
Section [381] Second Communicator Option Code
TLM Trouble Delay: Time, in 3 second checks, before the system will consider the phone line disconnected. Valid entries: [002] to [255]
(e.g., 3 x10 seconds = 30 seconds).
TLM Restoral follows the same delay.
Test Transmission Cycle (Land Line): Number of days between test transmission reporting events. Valid entries: [001] to [255].
For Future Use
Wireless Zone Low Battery Delay: Number of days the system will delay reporting a wireless low battery to the central station.
Valid entries: [000] to [255]. Program data [000] for no delay.
Delinquency Transmission Delay: Number of hours (Activity Delinquency) or days (Arming Delinquency) the panel will delay before transmitting
the event to the central station. Valid entries: [001] to [255].
Communication Cancel Window: Time, in seconds, after an alarm has occurred that the system will report a Communication Cancel reporting event
if the system is disarmed. They keypad will beep rapidly to indicate the Communication Cancel reporting event has been communicated successfully.
Valid entries: [001] to [255].
Option Description
[1] ON: the system communicator is enabled. OFF: the communicator is disabled.
[2] ON: the system transmits alarm restorals if the zone is restored and the bell has timed out. OFF: the system transmits alarm restorals
immediately when the zone is restored.
[3] ON: the panel uses rotary (pulse) dialing. OFF: the panel uses touchtone (DTMF) dialing
[4] ON: the panel will switch from touchtone dialing to rotary dialing after the 4th failed attempt to communicate.
OFF: the panel will use rotary dialing for all dialing attempts.
[5] ON: the system uses the Third Phone Number to back up the First Phone Number. OFF: the Third Phone Number is disabled.
[6] ON: the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
OFF: the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
[7] For future Use
[8] ON: the Delinquency feature follows zone activity. OFF: the Delinquency feature follows arming.
Option Description
[1] ON: the keypad beeps 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the keypad does not beep.
[2] ON: the bell output squawks 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the bell output does
not activate.
[3] ON: the system uses programmed reporting codes when transmitting using the SIA format.
OFF: the system automatically generates all reporting codes transmitted.
[4] ON: the system beeps the keypad 8 times after successfully transmitting a Closing reporting event. OFF: the keypad does not beep.