User guide
SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
MMC: 206 BARGE-IN
TYPE
DESCRIPTION:
Sets the type of barge-in that is permitted.
OPTION TYPE OF BARGE IN DESCRIPTION
0 NO BARGE-IN Barge-in feature is unavailable regardless of a
station’s barge-in status.
1 BARGE-IN WITH TONE Barge-in will have an intrusion tone and display at
the barged-in on station.
2 BARGE-IN WITHOUT TONE Barge-in is allowed. There is no barge-in tone or
display at the barged-in on station and the barging-
in station will be muted.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRSF 206
Display shows
BARGE IN TYPE
NO BARGE IN
2. Dial 0–2 to select barge-in type (e.g., 2)
OR
Press UP or DOWN to select barge-in type
and press RIGHT soft key
BARGE IN TYPE
WITHOUT TONE
3. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: NO BARGE -IN
RELATED ITEMS: MMC 301 ASSIGN STATION COS
MMC 701 ASSIGN COS CONTENTS