User guide
SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
MMC: 204 COMMON BELL CONTROL
DESCRIPTION:
Determines whether the common bell relay contacts have an interrupted or continuous closure
when activated. If interrupted is chosen, the relay follows an internal C.O. ring pattern of one
second closed followed by three seconds open.
As default, all common bell relay pairs are assigned as 380X.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor
SPK Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRSF 204
Display shows current setting
[3801]COM. BELL
CONTINUOUS
2. Dial common bell number
OR
Press UP or DOWN key to make selection of
common bell numbers and press RIGHT soft key to
advance cursor
[3802]COM. BELL
CONTINUOUS
3. Dial 0 for continuous or 1 for interrupted operation
OR
Use UP or DOWN to scroll through options
Press RIGHT soft key to return to step 2 above
[3802]COM. BELL
INTERRUPTED
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: CONTINUOUS
RELATED ITEMS: MMC 203 ASSIGN UA DEVICE
MMC 601 ASSIGN STATION GROUP