User guide
SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
MMC: 200 OPEN CUSTOMER PROGRAMMING
DESCRIPTION:
Used to open and close customer level programming. If programming is not opened and an
attempt is made to access a system MMC, the error message [NOT PERMIT] will be displayed. A
four digit passcode is required to access this MMC. Each digit can be 0–9. When opened, this
MMC enables access to all MMCs allowed in MMC 802 Customer Access MMC Number.
PROGRAM KEYS
UP & DOWN Select open or closed
KEYPAD Used to enter passcode
SPK Save data and advance to next MMC
TRSF Exit Programming
ACTION DISPLAY
1. Press TRSF 200
Display shows
ENABLE CUS.PROG.
PASSCODE:
2. Enter passcode ENABLE CUS.PROG.
PASSCODE:
Correct code shows ENABLE CUS.PROG.
DISABLE
Incorrect code shows ENABLE CUS.PROG.
PASSWORD ERROR
3. Press UP or DOWN arrow key to
select ENABLE or DISABLE and
Press RIGHT soft key
ENABLE CUS.PROG.
ENABLE
OR
Dial 1 for ENABLE,dial 0 for DISABLE
4. Press SPK to advance to MMC entry level and press
UP or DOWN key to select MMC OR
Enter MMC number and press RIGHT soft
key to enter MMC.
212:ALARM RING
SELECT PROG. ID
5. To log out press TRSF key.
DEFAULT DATA: CLOSED
RELATED ITEMS: MMC 201 CHANGE CUSTOMER PASSCODE
MMC 501 SYSTEM-WIDE TIMERS