User guide
SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
HOLD Used to clear previous entry
ACTION DISPLAY
1. Press TRSF 601
Display shows
[501] STN.GROUP
TYPE:NORMAL GRP
2. Dial group number (e.g., 505)
OR
Press UP or DOWN key to select group and press LEFT
soft key to move cursor to type of group, and DIAL
group type (0–2, e.g., 1)
OR
Press UP or DOWN key to make selection and press
LEFT soft key to move cursor to TYPE
[505] STN.GROUP
TYPE:NORMAL GRP
[505] STN GROUP
TYPE:VMAA
3. Dial feature option number (0–6, e.g., 0)
OR
Press UP or DOWN key to make selection and press
RIGHT soft key to move cursor to ring value
[505] STN GROUP
RING:SEQENTIAL
4. Dial ring option (0–2, e.g., 1)
OR
Press UP or DOWN key to make selection and press
LEFT soft key to move cursor back to RING or press right
soft key to return to step 2
[505] STN GROUP
RING:DISTRIBUTE
5. Dial next feature option and continue
OR
Press UP or DOWN key to select option
OR
Press LEFT soft key to return to step 2
[505] STN GROUP
RING:DISTRIBUTE
6. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: NORMAL GROUP
RELATED ITEMS: MMC 203 ASSIGN UA DEVICE
MMC 204 COMMON BELL CONTROL