User guide

SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL JUNE 1997
MMC: 510MESSAGE WAIT LED CADENCE
DESCRIPTION:
Provides the ability to customize the Message Wait LED cadence. There are two cadences
available. The two cadence are CONTINUOUS & INTERRUPT. The LED cadence control may be
changed from interrupt to continuous. The default setting of interrupt cadence is from 2000 to
2000.
The two options are as follows ;
CONTINUOUS : When the Message is accepted to the SLT that has Message Wait LED,
the Message wait LED will be turned on continuously.
INTERRUPT : On the above state, the LED will be filckered. The flickering interval can
be set/changed by MMC.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
HOLD Used to clear previous entry
ACTION DISPLAY
1. Press TRSF 510
2. Press UP or DOWN key to select cadence or
Press digit 0 or 1 via Dial Key Pad
MW LED CADENCE
CONTINUOUS LED
3. If you select the INTERRUPT LED mode, You can enter
the new value using keypad (default value is 2000)
MW LED CADENCE
INTERRUPT LED
MW LED CADENCE
2000 2000
4. Press TRSF button to store and exit
OR
Press SPK button to store and advance to next MMC
DEFAULT DATA: NONE
RELATED ITEMS:
NONE