User guide
SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
MMC: 502 FORWARD NO ANSWER TIMER
DESCRIPTION:
Allows the Forward No Answer timer to be changed on a per-station basis or for the entire
system.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ANS/RLS Used to select ALL
ACTION DISPLAY
1. Press TRSF 502
Display shows
[201] NO ANS FWD
010 SEC →_
2. Dial station number (e.g., 205)
OR
Press UP or DOWN key to select station and press
RIGHT soft key
OR
Press ANS/RLS to select all stations and press RIGHT
soft key
[205] NO ANS FWD
010 SEC →_
[ALL] NO ANS FWD
[[[SEC →_
3. Enter new value (must be three digits) via dial key pad
(e.g., 020)
System will return to step 2
[205] NO ANS FWD
010 SEC →020
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: TIMER IS SET FOR 15 SECONDS
RELATED ITEMS: MMC 102 CALL FORWARD