Dynamic Cooking Systems, Inc.
A Message To Our Customers Thank you for selecting this DCS Professional Vent Hood. Because of its unique features, we have developed this Use and Installation Guide. It contains valuable information on how to properly operate and maintain your new Vent Hood for years of safe and enjoyable cooking. To help serve you better, please fill out and return the Ownership Registration Card and keep this guide handy, as it will help answer questions that may arise as you use your New Vent Hood.
Table Of Contents INTRODUCTION: The DCS Vent Hood Models have been designed with the ultimate in household convenience in mind. Features include High Capacity,Variable Speed Blower, Commercial Style dishwasher-safe filters, Easyto-Clean inside liner, and Illuminating Halogen Lighting, all packaged in a stylish, welded-seam exterior. Before proceeding with installation, please read this installation guide and observe all safety precautions and warnings.
Safety Practices & Precautions WARNING: To reduce the risk of a range top grease fire: A) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oil slowly on low or medium settings. B) Always turn hood “ON” when cooking at high heat or when cooking flaming foods. C) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D) Use proper pan size.
Planning The Installation BACKDRAFT DAMPER: We recommend that a backdraft damper be used in all Vent Hood installations. Cold weather installations necessitate the use of a backdraft damper to minimize the flow of cold air into the room. A nonmetallic thermal break should also be installed to minimize conduction of outside temperatures through the ductwork. Locate the thermal break as close as possible to where the ducting enters the heated portion of the house.
Vent Hood Assembly FIG.08 DCS Duct Cover (6" or 12" Height) Rough-In Kit junction box Rough-In Kit A B junction box Through junction box on rough-in kit, connect to house wiring to blower motor Hood Inner Liner (Remove) ( 48" Model Liner Shown) FIG.07 Model DCS-IB12 Blower DCS VH 48 DCS VH12 36 Model DCS-IB6 Blower DCS VH 36 DCS VH 30 control panel Blower Hood Lights Hood Light Bulb-2ea. - + L. Heat Lamp Blower Speed (not all models) 5 R.
Vent Hood Installation (with soffit) SITE PREPARATION: This DCS Professional Vent Hood has been designed to accommodate installation into a 1) soffit structure (ceiling mount), or, for sites without a soffit structure. 2) directly into the wall through holes provided in the rear panel of the vent hood (wall mount). When mounting the hood to a soffit, it is recommended to also utilize the rear panel holes to gain additional stability and minimize any vibration noise.
Vent Hood Installation (with soffit) INSTALL VENT HOOD INTO SOFFIT: At this point in the installation process, the inner liner should be removed from the Hood and set aside (see-Pgs 5 & 6).With the liner set aside, there is clear access to the Soffit mounting holes and wall mounting holes in the rear panel of the unit. Once the soffit framing has been completed, place assembled vent hood (hood, rough-in kit, and ventilator) into place and secure hood to the soffit frame with 6 wood screws.
Vent Hood Installation (without soffit) SITE PREPARATION: In cases where the installation site does not have a soffit structure, the Vent Hood assembly may be secured directly to the wall from the rear of the unit. NOTE- When installing the vent hood directly to the rear wall, an adequate structural wall support (studs) must exist to secure the unit. NOTE- The DCS Duct Cover should be ordered and installed when installing the vent hood in a site without a soffit.
Finishing The Installation TO FINISH THE INSTALLATION: FIG.04 REAR VIEW of VENT HOOD (48" Model Shown) Once the ventilation hood has been mounted in place it will be necessary to install the electrical service. All electrical work should be done by a qualified electrician and must conform to all local standards. Refer to the wiring diagrams on Pgs. 14-15, for proper hook-up and grounding.
Duct Information GENERAL: 10" - When planning the path for ducting to the outside, keep in mind the following guidelines: - Minimize use of elbows and transitions in ductwork as to maximize air flow to outside of building. An efficient airflow path contributes to the overall efficiency of the Vent Hood. - DCS recommends the use of smooth wall ducting, not flexible ductwork.
DCS VH Series Specifications 12" " 6",12 " 18 Specify 48",36",30" Spec ify 48 DCS VH SERIES SOFFIT CHIMNEY DUCT COVER 25" ",36" ,30" 12" DCS VH SERIES HOODS 7" 7-1/4" 3" 3/4" 4-1/2" 23-1/2" 3" 10-1/4" 3/4" 23-1/2" 10-1/4" 10-1/4" 10-1/4" 12-1/4" 18-1/4" 10-1/4" 10-1/4" MODEL DCS IB6 BLOWER AND ROUGH IN KIT MODEL DCS IB12 BLOWER AND ROUGH IN KIT MODEL DCS IB6 BLOWER VOLTS HZ 120 60 AMPS 3.3 CFM 600 DUCT 7” ROUND MODEL DCS IB12 BLOWER 120 5.
Service HOW TO OBTAIN SERVICE: Before you call for service: 1) Is the circuit breaker tripped or the fuse blown? 2) Is there a power outage in the area? For warranty service, contact your local DCS authorized service agency. Provide him with the Model Number, Serial Number, and date of installation, and a brief description of the problem.
Warranty LENGTH OF WARRANTY: One (1) Year Full parts and Labor Covers the entire product Five (5) Year Limited warranty covering the switches and motor. DCS WILL PAY FOR All repair labor and parts found to be defective due to materials or workmanship for one full year “IN HOME” warranty during the first year of ownership. This does not apply if the unit was subjected to other than normal household use. Service must be provided by Authorized Factory Agent during normal working hours.
Wiring Diagram DCS VH 48 48" VENT HOOD WIRING DIAGRAM 1200 CFM MOTOR JUNCTION BOX (L1) BLK (N) WHT WN-3 (GROUND) GRN 6 8 MOTOR PLUG BLOWER MOTOR WHT BLK 5 16 7 1 2 3 4 5 CONNECTORS: 6 FEMALE 1 2 3 4 5 6 9 2 14 MALE USED ON HS MODELS ONLY 3 USED ON HS MODELS ONLY LEFT HEAT LIGHT brass 17 RIGHT HEAT LIGHT 17 brass zinc zinc 14 19 19 20 18 19 9 20 LEFT LIGHT 10 17 1a 1b 12 2 1 LEFT HEAT LIGHT SWITCH 10 14 15 2b 1a 1b 15 SPEED CONTROL 1a 1b 11 FAN SWITCH 4
(L1) BLK 36" / 30" VENT HOOD WIRING DIAGRAM (N) WHT 600 CFM MOTOR WN-3 BLOWER MOTOR 8 (GROUND) GRN 6 16 WH BLK 1 2 1 2 3 3 9 19 15 LEFT LIGHT 12 1 5 4 5 14 6 FEMALE 6 MALE 3 17 zinc 19 11 2 4 USED ON HS MODELS ONLY HEAT LIGHT brass CONNECTORS: 5 7 18 17 18 1a 1b HEAT LIGHT SWITCH 11 15 15 1a 2b SPEED CONTROL 1b 1a 1b 4 10 FAN SWITCH 14 3 WN-2 WN-1 LIGHT SWITCH 9 10 RIGHT LIGHT 13 12 1 2 Wiring Diagram DCS VH 30/36 JUNCTION BOX