Specifications
6
CONVERSION STICKER SAMPLES
A. From Natural Gas to LP B. From LP to Natural Gas
THIS CONVERSION RATING LABEL RELATES TO THE FOLLOWING
DCS MODELS:
CT-365
SUPPLY PRESSURE - MINIMUM 11" W.C.
MAXIMUM 14" W.C.
MANIFOLD PRESSURE - 10" W.C.
INPUT RATINGS - CENTER - 15,000 BTU/HR
FRONT - 10,000 BTU/HR
REAR - 10,000 BTU/HR
CONVERSION KIT PART. CKL-CT365
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM NATURAL GAS TO LP GAS WITH CONVERSION KIT
PA RT NO. CKL-CT365
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILTITY FOR THE CORRECTNESS OF THE
CONVERSION
THIS CONVERSION RATING LABEL RELATES TO THE FOLLOWING
DCS MODELS:
CT-365
SUPPLY PRESSURE - MINIMUM 6" W.C.
MAXIMUM 9" W.C.
MANIFOLD PRESSURE - 4" W.C.
INPUT RATINGS - CENTER - 17,500 BTU/HR
FRONT - 11,000 BTU/HR
REAR - 11,000 BTU/HR
CONVERSION KIT PART. CKN-CT365
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM LP GAS TO NATURAL GAS WITH CONVERSION KIT
PA RT NO. CKN-CT365
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILTITY FOR THE CORRECTNESS OF THE
CONVERSION