Specifications
2
IMPORTANT:
Disconnect the cooktop and the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test pressures greater than 1/2 psig.
Isolate the cooktop from the gas supply piping system by closing the individual manual
shut-off valve to the cooktop during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig.
STEP 2
REPLACE ALL BURNER AND VALVE ORIFICES
A. To Remove the Cooktop
Cooktop removal is required for:
Gas piping inspection
Wiring service
Valve replacement
Jet holder service
Manifold service
Indicator light replacement
Bezel replacement
To remove the cooktop:
1. Remove the valve knobs.
2. Remove the burner caps and main burner head (brass).
3. Remove the brass nut using a 1-1/16" socket or adjustable wrench and lift the burner ring from the
assembly.
4. Remove the large brass orifice tube from the center of each burner base using a 25/32" socket.
5. Lift each burner base and disconnect the push-on wire terminal from the spark electrode.Place the burner
base assemblies in a safe place.
Locator Pin
Electrode
Main Orifice
Burner Ring
Locking Nut
Burner Base
Burner Head
(Brass)
Burner Ring
(Aluminum)
Burner Cap
Simmer Orifice
Main Jet
Simmer Jet
Valve Bypass
Jet
4mm
7mm