User`s manual
GFK-2334A 3-1
PROFIBUS Master CPU Configuration
These configuration procedures are written for users with at least a basic knowledge of
the Machine Edition Logic Developer software and the Series 90-30 PLC. For help with
using the software, please see the software’s built-in help system.
Note: The PROFIBUS Master CPU does not support redundant masters.
Software configuration of the PROFIBUS master CPU consists of the following steps:
Adding the PROFIBUS master CPU to the configuration.
Configuring the CPU and PROFIBUS master parameters
Configuring network settings for the PROFIBUS master
Adding slave devices to the PROFIBUS master configuration.
Adding the PROFIBUS Master CPU to the Configuration
Add the IC693CPU366 module to the PLC rack configuration.
1. In the
Project tab of the Navigator, expand the Hardware Configuration
folder.
2. In the Hardware Configuration folder, right click the CPU Slot and select Replace
Module. The Module Catalog dialog box appears.
3. Select the IC693CPU366 PROFIBUS Master CPU and click the OK button. The
module is added to the PLC configuration in the Navigator window, and the module’s
Parameter Editor window appears.
3
Chapter