User guide
PROSTAR DCS COMPACT PROGRAMMING
TECHNICAL MANUAL PART 2 DECEMBER 1994
MMC: 311 ASSIGN SIM PARAMETER
DESCRIPTION:
NOTE: This MMC has no function on the DCS COMPACT at this time. It may be
used in the future.
Assigns and sets parameters for the serial interface module (SIM).
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
HOLD Used to clear previous entry
ACTION DISPLAY
1. Press TRSF 311
Display shows
[205] SIM PARA.
SIM TYPE :DTE
2. Enter station number of SIM (e.g., 220) via
dial keypad
[220] SIM PARA.
SIM TYPE :DTE
OR
Press UP or DOWN key to make selection
and press RIGHT soft key to move cursor
3a. Enter desired selection from table A (e.g., 01)
OR
[220] SIM PARA.
CALL MODE:MANUAL
Press UP or DOWN key to make selection
and press RIGHT soft key to move cursor
3b. Enter desired selection from table B
(e.g., 02)
[220] SIM PARA.
SIM TYPE :DTE
OR
Press UP or DOWN key to make selection
Press RIGHT soft key to move cursor to step
4
HOME
PAGE
Table of
Contents