User guide
PROSTAR DCS COMPACT PROGRAMMING
TECHNICAL MANUAL PART 2 DECEMBER 1994
MMC: 200 OPEN CUSTOMER PROGRAMMING
DESCRIPTION:
Used to open and close customer level programming. If programming is not
opened and an attempt is made to access a system MMC, the error message [NOT
PERMIT] will be displayed. A four digit passcode is required to access this MMC.
Each digit can be 0–9. When opened, this MMC enables access to all MMCs
allowed in MMC 802 Customer Access MMC Number.
PROGRAM KEYS
UP & DOWN Select open or closed
KEYPAD Used to enter passcode
SPK Save data and advance to next MMC
TRSF Exit programming
ACTION DISPLAY
1. Press TRSF 200
Display shows
ENABLE CUS.PROG.
PASSCODE:
2. Enter passcode
ENABLE CUS.PROG.
PASSCODE:
Correct code shows
ENABLE CUS.PROG.
DISABLE
Incorrect code shows
ENABLE CUS.PROG.
PASSWORD ERROR
3. Press UP or DOWN arrow key to select
ENABLE or DISABLE
ENABLE CUS.PROG.
ENABLE
Press RIGHT soft key
OR
Dial 1 for ENABLE or dial 0 for DISABLE
4. Press SPK to advance to MMC entry level
and press UP or DOWN key to select MMC
OR
Enter MMC number and press RIGHT soft
key to enter MMC
HOME
PAGE
Table of