PROSTAR DCS COMPACT PROGRAMMING
TECHNICAL MANUAL PART 2 DECEMBER 1994
MMC: 100 STATION LOCK
DESCRIPTION:
Allows the system administrator or technician to lock or unlock an individual station
or all stations simultaneously. The two options are as follows:
0 UNLOCKED Unlocks a locked station
1 LOCKED Locks an unlocked station
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
HOLD Used to clear previous entry
ANS/RLS Used to select ALL
ACTION DISPLAY
1. Press TRSF 100
Display shows
[201] STN LOCK
UNLOCKED
2. Dial station number (e.g., 205)
OR
[205] STN LOCK
UNLOCKED
Use UP and DOWN to select station
and use RIGHT soft key to move
cursor
OR
Press ANS/RLS to select all stations
[ALL] STN LOCK
??
3. Enter 0 to unlock or 1 to lock (e.g., 1)
OR
[205] STN LOCK
LOCKED
Press UP or DOWN key to make
selection and press RIGHT soft key
to return to step 2
HOME
PAGE
Table of
Contents