User guide
PROSTAR DCS COMPACT PROGRAMMING
TECHNICAL MANUAL PART 2 DECEMBER 1994
MMC: 502 FORWARD NO ANSWER TIMER
DESCRIPTION:
Allows the Forward No Answer timer to be changed on a per-station basis or for the
entire system.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ANS/RLS Used to select ALL
ACTION DISPLAY
1. Press TRSF 502
Display shows
[201] NO ANS FWD
010 SEC →_
2. Dial station number (e.g., 205)
OR
[205] NO ANS FWD
010 SEC →_
Press UP or DOWN key to select station and
press RIGHT soft key
OR
Press ANS/RLS to select all stations and
press RIGHT soft key
[ALL] NO ANS FWD
SEC →_
3. Enter new value via dial keypad (must be
three digits, e.g., 020)
[205] NO ANS FWD
010 SEC →020
System will return to step 2
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: TIMER IS SET FOR 15 SECONDS
RELATED ITEMS: MMC 102 CALL FORWARD