Installation Guide
6
CLEARANCE DIMENSIONS
GDE1-30 MODELS 
INCHES MM
A 
Minimum distance from combustible construction to rear of griddle 
(above counter)
12 305
B 
Minimum distance from combustible construction to sides of griddle 
(above counter)
12 305
BUILT-IN CLEARANCES
a
B
Clearances to combustible construction
Any materials of a building structure or decorative structure made 
of wood, compressed paper, plant fibres, vinyl/plastic or other 
materials that are capable of transferring heat or being ignited 
and burned. Such material shall be considered combustible even 
though flame-proofed, fire-retardant treated or surface-painted, 
or plastered.
Do not use this appliance under unprotected overhead 
combustible surfaces.
Insulated jacket
If the griddle is to be placed into a combustible enclosure, an 
approved insulated jacket is necessary. Insulated jackets are 
available from your dealer. Use only the DCS insulated jacket 
which has specifically been designed and tested for this purpose. 
Review the detail drawing shown and take into account the 
provisions shown for gas line connection clearance in the right 
rear corner. It is required that ventilation holes are provided in the 
enclosure to eliminate the potential build-up of gas in the event 
of a gas leak. The supporting ledges or deck must be level and 
flat and strong enough to support the grill and insulated jacket. 
The counter should also be level.
30” insulated jacket part number: 70859