User guide

P5040 DS Hardware Getting Started, Rev. 1.5
34 Freescale Semiconductor
LED Lights
10 LED Lights
Figure 8, below, lists the functioning of SuperHYDRA LED lights. See Table 9 for LED locations.
Table 9. P5040 DS (SuperHYDRA) LEDs
LED Color Name LED ON LED OFF
D3 Red ORIENT NOT
CORRECT
Incorrect processor orientation
in the socket
Correct processor orientation in the socket
D4 Blue PASS One of the following:
Successful FPGA initialization;
correct processor orientation;
and all on-board voltage is in
good condition
Register bit PX_CSR[7]=’0’
One of the following:
Power Off
Unsuccessful FPGA initialization
Incorrect processor orientation
Some/all of on-board voltage is in poor
condition
Register bit PX_CSR[7]=’1’
D5 Red FAIL One of the following:
Unsuccessful FPGA
initialization
Incorrect processor orientation
Some/all of on-board voltage is
in poor condition
Register bit PX_CSR[7]=’1’
One of the following:
Power Off
Successful FPGA initialization; correct
processor orientation; and all on-board
voltage is in good condition
Register bit PX_CSR[7]=’0’
D6 Green STAT0 Reset: lighted if LB_CS0_b=’0’
(BOOT)
Normal operation: lighted if
register bit PX_LED[0]=’1’
Register bit PX_LED[0]=’0’
D7 Green STAT1 Reset: lighted if LB_CS1_b=’0’
Normal operation: lighted if
register bit PX_LED[1]=’1’
Register bit PX_LED[1]=’0’
D8 Green STAT2 Reset: lighted if I
2
C1_SCL or
I
2
C4_SCL are non-existent
Normal operation: lighted if
register bit PX_LED[2]=’1’
Register bit PX_LED[2]=’0’
D9 Green ASLEEP Asserted: P3041/P5020
HRESET
P3041/P5020 HRESET unasserted
D10 Green STAT3 Reset: lighted if ASLEEP is
present
Normal operation: lighted if
register bit PX_LED[3]=’1’
Register bit PX_LED[3]=’0’
D11 Green STAT4 Normal operation: lighted if
register bit PX_LED[4]=’1’
Register bit PX_LED[4]=’0’