Specifications
2.1 Electrical
AC Input
• 230 VAC ± 10%, 50/60 Hz ± 2 Hz, 1 Phase
• 460 VAC ± 10%, 50/60 Hz ± 2 Hz, 1Phase
Maximum DC Field Output
• 200 VDC, 10 Amps for FR1000-000, 35 Amps for FR3500-000 @ 230 VAC
input
• 400 VDC, 10 Amps for FR1000-000, 35 Amps for FR3500-000 @ 460 VAC
input
Field Current Trim
• 6 to 1 Range
Current Regulation
• + 0.5% of set current
Operating Temperature Range
• 0 to 55 degrees C
Adjustments
• P1 Tach Gain
• P2 Tach Offset
• P3 Min Field Current
• P4 Max Field Current
• P5 Crossover Set Point
Crossover Application:
Armature Input
• 0 to 240 VDC
• 0 to 500 VDC
Maximum Tachometer Input
• 250 VDC
2.2 Physical