Technical data
Network OS Message Reference 63
53-1002489-01
Chapter
11
FVCS System Messages
FVCS-1002
Message <timestamp>, [FVCS-1002], <sequence-number>,, WARNING, <switch-name>, Test
FAB_VCS RAS rBridge ID (<port number>).
Probable Cause Indicates that the rBridge is valid.
Recommended
Action
If the message persists, execute the copy support ftp command and contact your switch service
provider.
Severity WARNING
FVCS-1003
Message <timestamp>, [FVCS-1003], <sequence-number>,, WARNING, <switch-name>, Possible
vLAG Split Detected vLAG - ifindex (<vLAG ifindex>) split rBridge(<split
rBridge>).
Probable Cause Indicates that the rBridge has left the cluster.
Recommended
Action
If the rBridge was not disabled on purpose, check if it is still connected to the cluster using the
show fabric isl command.
Severity WARNING
FVCS-2001
Message <timestamp>, [FVCS-2001], <sequence-number>,, WARNING, <switch-name>, FCS Primary
Update Send attempt Failed - reason (<Failure Reason>).
Probable Cause Indicates that the remote switch has rejected the update. Refer to the failure reason for more
details.
Recommended
Action
Execute the show fabric isl command to check the cluster connection status.
If the message persists, execute the copy support ftp command and contact your switch service
provider.
Severity WARNING