FCOE-1032
10
FCOE-1032
Message <timestamp>, [FCOE-1032], <sequence-number>,, INFO, <switch-name>, We are in WARM
RECOVERING state.
Probable Cause Indicates that the chassis is in a warm recovering state and therefore cannot perform the specific
actions.
Recommended
Action
Wait until the chassis is up.
Severity INFO
FCOE-1033
Message <timestamp>, [FCOE-1033], <sequence-number>,, WARNING, <switch-name>, FIP v1
FLOGI received - VF port in use.
Probable Cause Indicates that the port that received FLOGI has another device logged in already.
Recommended
Action
Currently, only the direct attached model is supported. Therefore, each port can have only one
FLOGI. The subsequent devices can log in as FDISCs.
Severity WARNING
FCOE-1034
Message <timestamp>, [FCOE-1034], <sequence-number>,, WARNING, <switch-name>, FIP/FCoE
frame received on priority <pkt_ctrlp->pri_in>. Discarding it because PFC/FCoE is
not enabled on this priority.
Probable Cause Indicates that the priority is not PFC or FCoE enabled.
Recommended
Action
Configure as required.
Severity WARNING
FCOE-1035
Message <timestamp>, [FCOE-1035], <sequence-number>,, INFO, <switch-name>, Virtual FCoE
port <port number> (<port wwn>) is online.
Probable Cause Indicates an administrative action on the FCoE port.
Recommended
Action
No action is required.
Severity INFO