Technical data
Network OS Message Reference 59
53-1002489-01
FCOE-1029
10
Recommended
Action
Some parameters are not getting exchanged correctly between the switch and the end device.
Reconfigure the port.
Severity ERROR
FCOE-1029
Message <timestamp>, [FCOE-1029], <sequence-number>,, WARNING, <switch-name>, Version
mismatch between FIP FDISC and root VN port.
Probable Cause Indicates that the FCoE Initialization Protocol (FIP) version does not match between the FLOGI and
FDISC.
Recommended
Action
Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.
Severity WARNING
FCOE-1030
Message <timestamp>, [FCOE-1030], <sequence-number>,, WARNING, <switch-name>, Version
mismatch between FIP LOGO and root VN port.
Probable Cause Indicates that the switch received an FIP LOGO but the device logged in with a different FIP version.
Recommended
Action
Make sure that the device that is trying to log in conforms to the FC-BB-5 standard.
Severity WARNING
FCOE-1031
Message <timestamp>, [FCOE-1031], <sequence-number>,, WARNING, <switch-name>, FCoE port
deleted port <prt> slot <slt>.
Probable Cause Indicates that the user port has been removed from the system.
Recommended
Action
If the message is displayed while the switch is booting up or powering down, no action is required.
However, if the message is displayed during normal operation, reboot the switch. If the problem
persists, contact your switch service provider.
Severity WARNING