Technical data

54 Network OS Message Reference
53-1002489-01
FABR-1012
9
FABR-1012
Message <timestamp>, [FABR-1012], <sequence-number>,, WARNING, <switch-name>, <function
stream>: no such type, <invalid type>.
Probable Cause Indicates that the fabric is not in the appropriate state for the specified process. This message is
rare and usually indicates a problem with the Network OS.
Recommended
Action
The fabric daemon will take proper action to recover from the error.
If the message persists, run the copy support command and contact your switch service provider.
Severity WARNING
FABR-1013
Message <timestamp>, [FABR-1013], <sequence-number>, FFDC, CRITICAL, <switch-name>, No
Memory: pid=<fabric process id> file=<source file name> line=<line number within
the source file>.
Probable Cause Indicates that there is not enough memory in the switch for the fabric module to allocate. This
message is rare and usually indicates a problem with the Network OS.
Recommended
Action
The system will recover by failing over to the standby CP.
If the message persists, run the copy support command and contact your switch service provider.
Severity CRITICAL
FABR-1014
Message <timestamp>, [FABR-1014], <sequence-number>,, ERROR, <switch-name>, Port <port
number> Disabled: rBridge IDs overlap. Insistent rBridge ID <RBridge ID> could not
be obtained. Principal is trying to assign rBridge ID <RBridge ID>.
Probable Cause Indicates that the switch received an rBridge ID other than the one it requested. The port was
disabled because the requested insistent rBridge ID could not be obtained.
Recommended
Action
Change the rBridge ID of the local node (if applicable) using the vcs rbridge-id command. You can
toggle the disabled port using the fabric isl enable and no fabric isl enable commands after the
rBridge ID change.
Severity ERROR