Technical data
Network OS Message Reference 49
53-1002489-01
EM-1068
8
EM-1068
Message <timestamp>, [EM-1068], <sequence-number>, FFDC, ERROR, <switch-name>, High
Availability Service Management subsystem failed to respond. A required component
is not operating.
Probable Cause Indicates that the High Availability (HA) subsystem has not returned a response within 4 minutes of
the request from the environmental monitor (EM). It usually indicates that some component has
not started properly or has terminated. The specific component that has failed may be indicated in
other messages or debug data. There are serious internal Network OS configuration or hardware
problems on the switch.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, execute the copy support command and contact your switch service
provider.
Severity ERROR
EM-2003
Message <timestamp>, [EM-2003], <sequence-number>,, ERROR, <switch-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause Indicates that the FRU has failed the Power-On Self-Test. Refer to the /tmp/post[1/2].slot#.log file
for more information on faults. To view this log file you must be logged in at the root level.The login
ID is Switch for non-bladed systems.
Recommended
Action
On bladed systems, try reseating the specified FRU.
On nonbladed switches, reboot or power cycle the switch.
If the problem persists:
• Execute the diag systemverification command to verify that the switch does not have hardware
problems.
• On bladed systems, replace the specified FRU; otherwise replace the switch.
Severity ERROR