Technical data

Network OS Message Reference 47
53-1002489-01
EM-1037
8
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the message persists, replace the FRU.
Severity WARNING
EM-1037
Message <timestamp>, [EM-1037], <sequence-number>,, INFO, <switch-name>, <FRU Id> is no
longer faulted.
Probable Cause Indicates that the specified power supply is no longer marked faulty, probably because its AC power
supply has been turned on.
Recommended
Action
No action is required.
Severity INFO
EM-1041
Message <timestamp>, [EM-1041], <sequence-number>,, WARNING, <switch-name>, Sensor values
for <FRU Id>: <Sensor Value> <Sensor Value> <Sensor Value> <Sensor Value> <Sensor
Value> <Sensor Value> <Sensor Value>.
Probable Cause Indicates that the sensors detected a warning condition. All the significant sensors for the FRU are
displayed; each contains a header.
This message can display:
Voltages in volts
Temperature in Celsius
Fan speeds in RPM
Recommended
Action
If the message is isolated, monitor the error messages on the switch. If the message is associated
with other messages, follow the recommended actions for those messages.
Severity WARNING
EM-1042
Message <timestamp>, [EM-1042], <sequence-number>, , WARNING, <switch-name>, Important
FRU header data for <FRU Id> is invalid.
Probable Cause Indicates that the specified FRU has an incorrect number of sensors in its FRU header-derived
information. This could mean that the FRU header was corrupted or read incorrectly or it is
corrupted in the object database, which contains information about all the FRUs.