Technical data
Network OS Message Reference 45
53-1002489-01
EM-1014
8
EM-1014
Message <timestamp>, [EM-1014], <sequence-number>,, ERROR, <switch-name>, Unable to read
sensor on <FRU Id> (<Return code>).
Probable Cause Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
FRU.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity ERROR
EM-1015
Message <timestamp>, [EM-1015], <sequence-number>,, WARNING, <switch-name>, Warm recovery
failed (<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, reboot or power cycle the switch.
Severity WARNING
EM-1016
Message <timestamp>, [EM-1016], <sequence-number>,, WARNING, <switch-name>, Cold recovery
failed (<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch. If the message persists, execute the copy support ftp command and contact
your switch service provider.
Severity WARNING
EM-1028
Message <timestamp>, [EM-1028], <sequence-number>, FFDC, WARNING, <switch-name>, HIL
Error: <function> failed to access history log for FRU: <FRU Id> (rc=<return
code>).
Probable Cause Indicates a problem accessing the data on the World Wide Name (WWN) card field-replaceable unit
(FRU) or the WWN card storage area on the main logic board.
The problems were encountered when the software attempted to write to the history log storage to
record an event for the specified FRU. This can indicate a significant hardware problem.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot,
or port. The return code is for internal use only.