Technical data

44 Network OS Message Reference
53-1002489-01
EM-1004
8
EM-1004
Message <timestamp>, [EM-1004], <sequence-number>, FFDC, CRITICAL, <switch-name>, <FRU
ID> failed to power on.
Probable Cause Indicates that the FRU failed to power on and is not being used. The FRU ID value is composed of a
FRU type string and an optional number to identify the unit, slot, or port.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity CRITICAL
EM-1012
Message <timestamp>, [EM-1012], <sequence-number>, FFDC, CRITICAL, <switch-name>, <FRU
Id> failed <state> state transition, unit faulted.
Probable Cause Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal
Network OS configuration or hardware problems on the switch.
Recommended
Action
Reboot or power cycle the switch.
Execute the diag systemverification command to verify that the switch does not have hardware
problems.
If the message persists, replace the FRU.
Severity CRITICAL
EM-1013
Message <timestamp>, [EM-1013], <sequence-number>,, ERROR, <switch-name>, Failed to
update FRU information for <FRU Id>
.
Probable Cause Indicates that the environmental monitor (EM) was unable to update the time alive or the original
equipment manufacturer (OEM) data in the memory of a FRU.
Recommended
Action
The update is automatically attempted again. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity ERROR