Technical data

Network OS Message Reference 39
53-1002489-01
Chapter
6
EANV System Messages
EANV-1001
Message <timestamp>, [EANV-1001], <sequence-number>,, ERROR, <switch-name>, Port <port
number> port fault. Change the SFP or check the cable.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between the peer ports.
Recommended
Action
Verify that compatible SFPs are used on the peer ports, the SFPs have not deteriorated, and the
Fibre Channel cable is not faulty. Replace the SFPs or the cable if necessary.
Severity ERROR
EANV-1002
Message <timestamp>, [EANV-1002], <sequence-number>, FFDC, ERROR, <switch-name>, Port
<port number> chip faulted due to an internal error.
Probable Cause Indicates an internal error. All the ports on this chip will be disrupted.
Recommended
Action
Reboot the system at the next maintenance window.
Severity ERROR
EANV-1003
Message <timestamp>, [EANV-1003], <sequence-number>,, CRITICAL, <switch-name>, S<slot
number>,C<chip index>: HW ASIC Chip error. Type = 0x<chip error type>, Error =
<chip error string>.
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
When this error occurs, reboot the system at the next maintenance window.
Severity CRITICAL