Technical data
Network OS Message Reference 197
53-1002489-01
ZONE-1029
41
ZONE-1029
Message <timestamp>, [ZONE-1029], <sequence-number>,, WARNING, <switch-name>, Restoring
zone cfg from flash failed - bad config saved to <config file name> [<return
code>].
Probable Cause Indicates that the zone configuration restored from the flash was faulty.
Recommended
Action
This error will save the faulty zone configuration in the zoned core file directory.
If the message persists, execute the copy support ftp command and contact your switch service
provider.
Severity WARNING
ZONE-1030
Message <timestamp>, [ZONE-1030], <sequence-number>,, WARNING, <switch-name>, Converting
the zone DB for PID format change failed.
Probable Cause Indicates that the current zone database could not be converted to reflect the PID format change.
Most likely this is caused due to the size of the zone database.
Recommended
Action
Change the PID format back to its original format. Reduce the size of the zone database. Then you
can change the PID format to the requested format.
Severity WARNING
ZONE-1032
Message <timestamp>, [ZONE-1032], <sequence-number>,, ERROR, <switch-name>, rBridge
<rBridge number> Max Zone DB size <max zone db size>.
Probable Cause Indicates that the specified rBridge does not have enough memory for the zone database being
committed.
Recommended
Action
Reduce the size of the zone database and retry the operation.
Severity ERROR
ZONE-1033
Message <timestamp>, [ZONE-1033], <sequence-number>,, ERROR, <switch-name>, rBridge
<rBridge number> Lowest Max Zone DB size.
Probable Cause Indicates that the specified rBridge has the lowest memory available for the zone database in the
fabric. The zone database must be smaller than the memory available on this rBridge.