Technical data

196 Network OS Message Reference
53-1002489-01
ZONE-1024
41
ZONE-1024
Message <timestamp>, [ZONE-1024], <sequence-number>,, INFO, <switch-name>, <Information
message>.
Probable Cause Indicates that the zoning enabled-configuration cfg-action cfg-save command was executed
successfully.
Recommended
Action
No action is required.
Severity INFO
ZONE-1027
Message <timestamp>, [ZONE-1027], <sequence-number>,, INFO, <switch-name>, Zoning
transaction aborted <error reason>. <AD Id>.
Probable Cause Indicates that the zoning transaction was aborted due to a variety of potential errors. The error
reason variable can be one of the following:
Zone Merge Received: The fabric is in the process of merging two zone databases.
Zone Config update Received: The fabric is in the process of updating the zone database.
Bad Zone Config: The new config is not viable.
Zoning Operation failed: A zoning operation failed.
Shell exited: The command shell has exited.
Unknown: An error was received for an unknown reason.
User Command: A user aborted the current zoning transaction.
Switch Shutting Down: The switch is currently shutting down.
Recommended
Action
Many of the causes of this error message are transitory, for example, because two administrators
are working with the zoning database concurrently. If you receive this error, wait for few minutes
and try again. Verify that no one else is currently modifying the zone database.
Severity INFO
ZONE-1028
Message <timestamp>, [ZONE-1028], <sequence-number>,, WARNING, <switch-name>, Commit zone
DB larger than supported - <zone db size> greater than <max zone db size>.
Probable Cause Indicates that the zone database size is greater than the limit allowed by the fabric. The limit of the
zone database size depends on the lowest level switch in the fabric. Older switches have less
memory and force a smaller zone database for the entire fabric.
Recommended
Action
Edit the zone database to keep it within the allowable limit for the specific switches in your fabric.
Severity WARNING