Technical data

190 Network OS Message Reference
53-1002489-01
VCS-1004
40
FDS: VCS is enabled on a node that was not a member of the VCS cluster, or the node rejoined
the VCS cluster after the reload command was issued or the inter-switch link (ISL) toggled.
Recommended
Action
No action is required.
Severity INFO
VCS-1004
Message <timestamp>, [VCS-1004], <sequence-number>, VCS, ERROR, <switch-name>, Event: VCS
node add, Coordinator IP: <Co-ordinator's Public IP>, VCS ID: <VCS Id>, Status:
rBridge ID <RBridge-id of Switch That Failed To Be Added> (<IP of Switch That
Failed To Be Added>) failed to be added to VCS cluster, Reason: <Error Reason>.
Probable Cause Indicates that a node failed to be added to the VCS cluster. Refer to the reason code for the cause
of the error.
Recommended
Action
Refer to reason code for possible action.
Severity ERROR
VCS-1005
Message <timestamp>, [VCS-1005], <sequence-number>, VCS, INFO, <switch-name>, Event: VCS
node rejoin, Coordinator IP: <Co-ordinator's Public IP>, VCS ID: <VCS Id>, Status:
rBridge ID <RBridge-id of Rejoined Switch> (<IP of Rejoined Switch>) rejoined VCS
cluster.
Probable Cause Indicates that the DCM node has gone offline and returned online without any configuration
changes.
Recommended
Action
No action is required.
Severity INFO
VCS-1006
Message <timestamp>, [VCS-1006], <sequence-number>, VCS, ERROR, <switch-name>, Event: VCS
node rejoin, Coordinator IP: <Co-ordinator's Public IP>, VCS ID: <VCS Id>, Status:
rBridge ID <RBridge-id of Switch That Failed To Rejoin> (<IP of Switch That Failed
To Rejoin>) failed to rejoin VCS cluster, Reason: <Error Reason>.
Probable Cause Indicates that the DCM node has failed to rejoin the existing VCS cluster. Refer to the reason code
for the cause of the error.