Technical data
Network OS Message Reference 185
53-1002489-01
Chapter
38
TS System Messages
TS-1002
Message <timestamp>, [TS-1002], <sequence-number>,, INFO, <system-name>, <Type of clock
server used> Clock Server used instead of <Type of clock server configured>: locl:
0x<code> remote: 0x<code>.
Probable Cause Indicates the switch time synchronization was not sourced from the Type of clock server
configured, instead, an alternate server was used, indicated by Type of clock server used. The type
of clock server used or configured may be one of the following:
• LOCL
Local switch clock
• External
External NTP server address configured
This may be logged during temporary operational issues such as IP network connection issues to
the external clock server. If the message does not recur, it should be ignored.
Recommended
Action
Run the show ntp status command to verify that the switch has the clock server IP configured
correctly. Verify this clock server is accessible to the switch and functional. If it is not accessible or
functional, either configure a accessible and functional clock server or reset the clock server to
LOCL.
Severity INFO
TS-1008
Message <timestamp>, [TS-1008], <sequence-number>,, WARNING, <system-name>, <New clock
server used> Clock Server used instead of <Old server configured>.
Probable Cause Indicates there is a change in the source of switch time synchronization to the switch. Another
clock server in the list of clock servers configured is being used. This happens when the network
time protocol (NTP) query to the current active external clock server fails.
Recommended
Action
No action is required. New clock server synchronization may adjust the clock time.
Severity WARNING