Technical data
Network OS Message Reference 161
53-1002489-01
SSMD-1216
34
SSMD-1216
Message <timestamp>, [SSMD-1216], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming interface 0x<Interface ID> Pause.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing interface Pause feature.
Recommended
Action
Delete and reapply QoS Pause policy.
Restart or power cycle the switch.
Severity WARNING
SSMD-1217
Message <timestamp>, [SSMD-1217], <sequence-number>,, WARNING, <switch-name>, QoS CEE
could not comply with FCoE scheduler policy for CEE Map <CEE Map name>.
Probable Cause Indicates that the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE
configuration into an Enhanced Transmission Selection (ETS) scheduler policy implementable by
the dataplane ASIC.
Recommended
Action
Redefine CEE Map and FCoE into a configuration that translates into an ETS scheduler policy
requiring 8 or fewer Traffic Class.
Severity WARNING
SSMD-1218
Message <timestamp>, [SSMD-1218], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming interface 0x<Interface ID> Priority Tag.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing interface Priority Tag feature.
Recommended
Action
Delete and reapply QoS interface Priority Tag policy.
Restart or power cycle the switch.
Severity WARNING
SSMD-1219
Message <timestamp>, [SSMD-1219], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming interface 0x<Interface ID> CoS7 TCAM.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing interface CoS7 TCAM feature.