Technical data
Network OS Message Reference 157
53-1002489-01
SSMD-1202
34
SSMD-1202
Message <timestamp>, [SSMD-1202], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming interface 0x<Interface ID> 802.3x Pause flow control.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in the
programming dataplane ASIC for enforcing interface 802.3x Pause flow control feature.
Recommended
Action
Delete and reapply QoS 802.3x Pause flow control policy.
Restart or power cycle the switch.
Severity WARNING
SSMD-1203
Message <timestamp>, [SSMD-1203], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming interface 0x<Interface ID> PFC flow control.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in the
programming dataplane ASIC for enforcing interface PFC flow control feature.
Recommended
Action
Delete and reapply QoS PFC flow control policy.
Restart or power cycle the switch.
Severity WARNING
SSMD-1204
Message <timestamp>, [SSMD-1204], <sequence-number>,, WARNING, <switch-name>, QoS failed
initializing ASIC <ASIC slot number>/<ASIC chip number>.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in
initializing the dataplane ASIC QoS infrastructure.
Recommended
Action
Restart or power cycle the switch.
Severity WARNING
SSMD-1205
Message <timestamp>, [SSMD-1205], <sequence-number>,, WARNING, <switch-name>, CEE failed
programming ETS policy for CEE Map <CEE Map name>.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in
programming dataplane ASIC for enforcing CEE Map ETS feature.