Technical data
156 Network OS Message Reference
53-1002489-01
SSMD-1005
34
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
SSMD-1005
Message <timestamp>, [SSMD-1005], <sequence-number>,, ERROR, <switch-name>, SSM startup
failed.
Probable Cause Indicates that the Data Center Ethernet (DCE) SSM encountered an unexpected, severe error
during basic startup and initialization.
Recommended
Action
Restart or power cycle the switch.
If condition persists then download a new firmware version using the firmware download
command.
Severity ERROR
SSMD-1200
Message <timestamp>, [SSMD-1200], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming ASIC <ASIC slot number>/<ASIC chip number> Multicast Rate Limit.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in the
programming dataplane ASIC for enforcing Multicast Rate Limit feature.
Recommended
Action
Delete and reapply QoS Multicast Rate Limit policy.
Restart or power cycle the switch.
Severity WARNING
SSMD-1201
Message <timestamp>, [SSMD-1201], <sequence-number>,, WARNING, <switch-name>, QoS failed
programming ASIC <ASIC slot number>/<ASIC chip number> Multicast Tail Drop.
Probable Cause Indicates that the DCE System Services Manager (SSM) encountered an unexpected error in the
programming dataplane ASIC for enforcing Multicast Tail Drop feature.
Recommended
Action
Delete and reapply QoS Multicast Tail Drop policy.
Restart or power cycle the switch.
Severity WARNING