Technical data
Network OS Message Reference 155
53-1002489-01
Chapter
34
SSMD System Messages
SSMD-1001
Message <timestamp>, [SSMD-1001], <sequence-number>,, ERROR, <switch-name>, Failed to
allocate memory: (<function name>).
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the show processes memory command.
Restart or power cycle the switch.
Severity ERROR
SSMD-1002
Message <timestamp>, [SSMD-1002], <sequence-number>,, ERROR, <switch-name>, Failed to
initialize <module> rc = <error>.
Probable Cause Indicates that initialization of a module within the System Services Manager (SSM) has failed.
Recommended
Action
Download a new firmware version using the firmware download command.
Severity ERROR
SSMD-1003
Message <timestamp>, [SSMD-1003], <sequence-number>,, ERROR, <switch-name>, Failed to
lock semaphore mutex: (<function name>).
Probable Cause Indicates that the specified function has failed to lock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
SSMD-1004
Message <timestamp>, [SSMD-1004], <sequence-number>,, ERROR, <switch-name>, Failed to
unlock semaphore mutex: (<function name>).
Probable Cause Indicates that the specified function failed to unlock the mutex (semaphore).