Technical data
Network OS Message Reference 133
53-1002489-01
Chapter
29
RTWR System Messages
RTWR-1001
Message <timestamp>, [RTWR-1001], <sequence-number>,, ERROR, <switch-name>, RTWR
<routine: error message> 0x<detail 1>, 0x<detail 2>, 0x<detail 3>, 0x<detail 4>,
0x<detail 5>.
Probable Cause Indicates that an error occurred in Reliable Transport Write and Read (RTWR) due to one of the
following reasons:
• The system ran out of memory.
• The domain may be unreachable.
• The frame transmission failed.
• An internal error or failure.
The message contains the name of the routine that has an error and other error-specific
information. Refer to values in details 1 through 5 for more information.
Recommended
Action
Execute the reload command to reboot the switch.
Severity ERROR
RTWR-1002
Message <timestamp>, [RTWR-1002], <sequence-number>,, WARNING, <switch-name>, RTWR <error
message> 0x<detail 1>, 0x<detail 2>, 0x<detail 3>, 0x<detail 4>, 0x<detail 5>.
Probable Cause Indicates that RTWR has exhausted the maximum number of retries for sending data to the
specified rBridge. The message details are as follows:
• error message: Maximum number of retries exhausted
• detail1: Port
• detail2: rBridge
• detail3: Retry Count
• detail4: Status
• detail5: Process ID
Recommended
Action
Execute the show fabric all command to verify that the specified rBridge ID is online.
Enable the switch with the specified rBridge ID.